CT-3420-BONE Toilets ELONGATED Bone color 1-PIECE Water Closet, UPC APPROVED Soft closing seat & cover
Color
Bone ( they also called Biscute or ivery)
Nominal Overall Dimensions:
30" x 20-3/4" x 24-1/4"
(760mm x527mm x 615mm)
• Elongated siphon action bowl UPC APPROVED
• Front bowl jet for superior performance
• Vitreous china construction
• Includes color matched bolt caps
• Designer matched seat included
Hydraulic performance, water surface area, trap
seal depth, ballpass diameter, and all fixture
dimensions meet or exceed ANSI Standard
A112.19.2M requirements.
THIS TOILET IS DESIGNED TO ROUGH-IN AT A MINIMUM DIMENSION OF 12” (305MM)
FROM FINISHED WALL TO C/L OF OUTLET.
SUPPLIED WITH INSTALLATION TEMPLATE.
INCLUDES FLEX SUPPLY WITH INTEGRAL SHUTOFF VALVE, SEAT, AND BOLT CAPS.
★ DIMENSIONS SHOWN FOR LOCATION OF CONCEALED SUPPLY ARE SUGGESTED.
IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances
established by ANSI Standard A112.19.2M.
ELONGATED Designer piece Suneli Water Closet TOILETS, CT-3120 TOILET, WHITE & BONE COLORS soft closing Seat and cover
• Low-consumption (6.0 Lpf/1.6 gpf) • Low-profile, one-piece toilet. White, Black, Bone Colors
• Elongated siphon action bowl and tank with concealed trap way
• Includes color-matched Rise and Shine™ plastic seat and cover (#5324.019) with
easy-to-clean, lift-off hinge system • Fully-glazed trap way • 100% factory flush tested
Certifications - Meets or Exceeds the Following Specifications:
• ASME A112.19.2M for Vitreous Fixtures - includes Flush Performance, Ball Pass Diameter,
Trap Seal Depth and all Dimensions. Similar to Kohler & toto or Home Depot, Lowe’s and save $200.00
II. DRAIN, WASTE AND VENT
1. Provide detail on drain waste, and vent systems. Include size of pipe and pipe materials.
2. Vent sizes through the roof must equal or exceed the size of the building sewer in area. UPC sec. 904.1
3. Rest rooms in excess of one water closet or containing one water closet and one urinal require a trap primed floor drain.
UPC sec. 411.2.1
4. Commercial laundries and common laundries of multi-family dwellings require a trap primed floor drain. UPC sec.
411.2.3
5. Commercial kitchens require a trap-primed floor drain in cooking and/or prep areas. UPC sec. 411.2.2
6. Show all required cleanout location and sizes. UPC sec. 707.4
7. All food prep sinks and similar equipment shall be indirectly connected to the drainage system by means of an airgap. CPC
sec. 801.2.3
8. All floor drains, mop sinks, prep sinks and floor sinks and drains receiving grease waste from any food prep sinks must
drain through a grease trap or interceptor, depending upon the amount of of grease receiving fixtures. UPC sec. 1014.1
9. Size of Hydromechanical Grease Interceptors is determined using Table 10-2 of the CPC.
10. Size of Gravity Grease Interceptors is determined using Table 10-3 of the CPC.
11. Gravity Grease Interceptors shall not be installed in any portion of the building where food is handled. CPC sec.
1014.3.4.1
12. Elevator sumps are to be drained through an oil separator before draining into the sanitary system, or the sump is to be
drained to a holding tank with a liquid level alarm. UPC sec. 1009.1
13. Structure requires rain water system based on 4 inch rainfall per hour. Include square footage of roof per area served by
rain water system. UPC app. D
14. A sample box or port is required immediately downstream of grease interceptor per city of Huntington Beach.
15. Secondary roof drainage shall be provided by the use of roof scuppers or a secondary roof drain per sections 1101.11.2.1
and 1101.11.2.2
16. Total number of water closets for women must equal the total number of water closets and urinals required for men
excepting retail or wholesale stores UPC table 4-1 footnote # 14.
17. Use Table 4-1 and Table A of the 2007 California Plumbing Code to determine minimum number of fixtures required for
occupancy denoted in plans.
|